阴APP导航

ProjectNew Build
Project Number24eN749964
Address7 Harry Walker PKY
Site SuperintendentMike Calderone
General ContractorRice Commercial Group
75 Tiverton Markham Ont Ont L4R M48 Canada
Comments

Steel Roof deck onsite.

Profile Deck & Shear Studs Ltd. is certified to CSA Standard W47.1 鈥溡魽PP导航 of companies for fusion welding of steel鈥 in Division 3 and has been sublet the work by Linesteel (1973) Limited who is certified in Division 2, therefore, does meet the requirements of CSA S16 Clause 24.3 which is referenced in the National & Provincial Building Codes Section 4.3.4.1.

NBCC Section 4.3.4.1: "Building and their structural members made of structural steel shall conform to CSA S16 鈥淒esign of Steel Structures.鈥

CSA S16 Clause 24.3: 鈥淔abricators and erectors responsible for welding structures fabricated or erected under this Standard shall meet the requirements of CSA W47.1, CSA W55.3 or both, as applicable in Division 1 or Division 2. Part of the work may be sublet to a Division 3 fabricator or erector; however, the Division 1 or Division 2 fabricator or erector shall retain responsibility for the sublet work.鈥

Site ContactMike Calderone
CWB RepresentativeBrian Howe
Date2025-03-26