APP

ProjetColdstream Drive
Numéro du projet24 015170 MX
Adresse580 Coldstream Dr Waterloo, On N2V 2H3
Surintendant du siteChance O'Brien
Entrepreneur généralModern Edge Developments
295 Weber St. unit 4 Kitchener Ontario N2H 4A7 Canada
Commentaires

Supply of hollow core with rebar by Prestressed systems Inc.

Prestressed Systems Inc. is not certified to CSA Standard W186 “Welding of reinforcing bars in reinforced concrete construction” and, therefore, does not meet the requirements of CSA A23.3 Clause 12.14.3.2 which is referenced in the National & Provincial Building Codes Section 4.3.3.1.

NBCC Section 4.3.3.1: “Buildings and their structural members made of plain, reinforced and pre-stressed concrete shall conform to CSA A23.3, “Design of concrete structures”.

CSA A23.3 Clause 12.14.3.2: "All welding shall comply with CSA W186."

Contact sur le siteChance O'Brien
Représentant de la CWBBrian Lieske
Date2025-03-14